Suitable for Technicon AAII, Bran+Luebbe AAII, Bran+Luebbe AA3, SEAL Analytical AA3 HR, SEAL Analytical AA500
Use Only GENUINE SEAL Parts - SEAL Analytical is the ONLY source of GENUINE ORIGINAL parts and consumables for SEAL, formerly Technicon, formerly Bran+Luebbe AutoAnalyzer II, AutoAnalyzer 3, AA500, TrAAcs, QuAAtro.
Ensure Optimum Performance - The best performance of your Analyzer can only be guaranteed when using GENUINE parts and consumables. Other companies offer inferior replicas or refurbished items using our Technicon/ Bran+Luebbe/ SEAL part numbers.
Contact SEAL Analytical for your Genuine AutoAnalyzer parts.
C3 Tubing Connector
Part Number: 116-0202-03
Package of 1
AE Tubing Glass Trans. Access
Part Number: 116-0223-48
Package of 1
A Injection Fitting
(3 point)
Part Number: 116-0489-01
Package of 1
B Injection Fitting (2 point)
Part Number: 116-0492-01
Package of 1
Reagent Lines >/= 0.80mL/min
Part Number: 116-0528-01
Package of 3 mtr
Reagent Lines
0.025-0.60mL/min
Part Number: 116-0536-07
Package of 3 mtrs
Flowcell Sleeving Tubing 0.090 ID
Part Number: 116-0536-16
Package of 3 mtrs
Manifold Sleeving Tubing-Butt Joints
Part Number: 116-0536-18
Package of 3 mtr
A10 Sample Fitting-Single Injection Point
Part Number:116-B034-01
Package of 1
PT27-Sapphire Glass-2 way splitter
Part Number: 116-B332-01 Package of 1
Pump Tubing Organizer
Part Number: 116+K998-01
Package of 1
Pharmed Tubing, Airbar
Part Number: 117+0540-07
Package of 3 mtr
10T L.H Coil 2.0mm
Part Number: 157-0226-01
Package of 1
10T R.H Coil 2.0mm
Part Number: 157-0251-01
Package of 1
Cadmium Coil, 6 Turn
Part Number: 165-0301-03
Package of 1
Filter Assembly-XX is first 2 digits in wavelength
Part Number: 165+B044-XX
Package of 1
Sample Rack 21 Pos
Part Number: 168-1006-01
Package of 1
Sample Rack 60 Pos
Part Number: 168+1010-01
Package of 1
Sample Rack 90 Pos
6X15 13mm
Part Number: 168+1011-01
Package of 1
PTFE Sleeved & Lined XY2
Part Number: 168+B532-03
Package of 1
Flowcell,10mm
Part Number: 169+B045-10
Package of 1
Lamp AA3 /QuAAtro
AA3 /QuAAtro
Part Number: 169+B143-01
Package of 1
Back Glassware
Colorimeter
Part Number: 169+G140-01
Package of 1
Front Glassware
Colorimeter
Part Number: 169+G141-01
Package of 1
5 Turn Coil Right
Part Number: 170-0103-03
Package of 1
Dialyzer Membrane- Pre-mounted- 6 Inch
Part Number: 170-0406-04
Package of 12
5 Turn Coil Left
Part Number: 170-0426-01
Package of 1
Dialyzer Membrane- Pre-mounted-12 Inch
Part Number: 170-0472-04
Package of 12
AT Connecting Tube
Part Number: 170-G017-01
Package of 1
AH Tube Conn
Part Number: 170-G064-01
Package of 1
AY Glass Tube
Part Number: 170-G071-01
Package of 1
Reagent Filter
Part Number: 178-3985-XX
Package 50 (178-3985-01)
Package of 1000 (178-3985-02)
Reagent Straw
Part Number: 178-4061-01
Package of 1
Nitrogen Bag w/ cap combo
Part Number: 178-N000-01
Package of 1
Coil Clip
Part Number: 509-0121-01
Package of 1
Splitter (medium flow)
PT18-metal
Part Number: 518-0230-01K
Package of 1
Air line Tubing PE
(between airbar & pump tube)
Part Number: 562-2002-01
Package of 3 mtr
PE Sample Line Tubing, Polyethylene 0.03" ID
Part Number: 562-2015-01
Package of 3 mtr
Kit Inclusions:
116+K996-01
4 Way Valve Maintenance Kit Inclusions
1 ea 566+0010-01 4 way valve
2 ea 508+2011-01 Nut, Black 4 way valve
2 ea 508+2011-06 Nut, Red 4 way valve
4 ea 508+2012-01 Ferrule, Blue 4 way valve
1 ea 562-2015-01 Tubing PE 0.030 ID pkg 3 meter
1 ea 116-0536-11 Tubing std 0.051 ID pkg 3 meter
20 ea 116-0004-01 N6 Nipple
1 ea JR-20154 Flanging Tool, PE
116+K997-01
Flowcell Cleaning & Storage Kit
Cleaning Solution Formulation
Solution #1: a N HC1
21.5ml concentraged HCI diluted to 250ml
Solution #2: 1 N NaOH
10 g NaOH pellets diluted to 250 ml
Solution #3: 10% v/v Bleach
25ml bleach diluted to 250 ml
Solution #4: Deionized Water
Solution #5: System Wash Solution
Tools:,
Tube #1: 2 ea 15" 116-0528-01 Tygon Tubing sleeved one end with 116-0536-16 Tygon Tubing
Tube #2: 2 ea 5" 116-0528-01 Tygon Tubing sleeved both ends with 116-0536-16 Tygon Tubing
60ml Syringe
116+K997-02
Flowcell Cleaning Kit with Flowcell
Cleaning Solution Formulation
Solution #1: 1 N HCI
21.5 ml concentrated HCI diluted to 250 ml
Solution #2: 1 N Na OH
10 g NaOH pellets diluted to 250 ml
Solution #3: 10% v/v Bleach
25 ml bleach diluted to 250ml
Solution #4: Deionized Water
Solution #5: System Wash Solution
Tools:
Tube #1: 2 ea 15" 116-0528-01 Tygon Tubing sleeved one end with 116-0536-16 Tygon Tubing
Tube #2: 2 ea 5" 116-0528-01 Tygon tubing sleeved both ends with 116-0536-16 Tygon Tubing
60ml Syringe
116+K999-01
AA3 Tubing Kit
116-0536-18 0.110 ID Tygon
116-0536-16 0.090 Id Tygon
116-0536-09 0.040 ID Tygon
116-0528-01 0.062 ID Tygon
116-0536-07 0.030 ID Tygon
116-0536-04 0.015 ID Tygon
117+0540-07 Pharmed
562-2002-01 0.015 PE
562-2015-01 0.030 PE