Register
|
Login
Home
About SEAL
About SEAL Analytical
Events and Exhibitions
SEAL Press Release
Employment
Technical Support Chemist
Development Chemist
Your Privacy
Markets
Wastewater Analysis
Water Analysis
Olympic Water Quality Danger
Case Study - Lake Superior University AQ1
AutoAnalyzer Protects BASF From Impurities in Water
University of Portsmouth
An Australian Lab's Key to Success
Seawater Analysis
Ocean-going lab- Real test of Nutrient Analyzer
HOT Case Study
Australian Institute of Marine Science
Researchers investigate ultra-low Mediterranean nutrient levels
Soil & Plant Analysis
Fertilizer Analysis
Pharmaceutical
Food& Beverage Analysis
Tobacco Analysis
Products
Discrete Analyzers
AQ400 Discrete Analyzer
AQ300 Discrete Analyzer
AQ270 Discrete Analyzer
AQ2 Discrete Analyzer
AQ2 Automatizada Integrated Analyzer
AQ Software
Segmented Flow Analyzers
QuAAtro39 AutoAnalyzer
AA500 AutoAnalyzer
AA3 HR AutoAnalyzer
AA100 AutoAnalyzer
AutoAnalyzer II
AACE AutoAnalyzer Software
Robotic Handling Systems
MiniLab BOD Analyzer
MiniLab Multi-Parameter Robot
PH & Electrical Conductivity
Digestion
Digestion Block-BD50/ BD28
Block Digestion Temp Accuracy
SmartBlock ll Graphite Heating Block
Deena3 Metals Digestion
DEENA II Metals Digestion
Samplers
AutoSamplers
Methods
Methods Overview
AutoAnalyzer Methods
AutoAnalyzer Multi-test Methods
QuAAtro Multi-test Methods
AA3 PO4 Application Notes
QuAAtro P04 Application Notes
Discrete Methods
Discrete Analyzer EPA Methods
Support
Technical Support
Support Contracts
Service and Repairs
Software Upgrades
Customer Training
AQ400 Customer Support
AQ2 Customer Support
AQ1 Customer Support
AA3 Customer Support
QuAAtro Customer Support
Parts
AutoAnalyzer Parts (AA2-AA3)
Pump Tubes
Transmission Tubing
NOx 4 way Valve Maintenance Kit
AutoAnalyzer Parts AA100-AA1
AutoAnalyzer AA100-AA1 Pump Tubes
QuAAtro - TrAAcs Parts
QuAAtro Pump Tubes
AQ400 Consumables & Parts
AQ2 Consumables & Parts
AQ1 Consumables & Parts
BD28/BD50/ AIM 600 Block Digestion Parts
News
SEAL Newsletter
US Newsletter Winter 2019
US Newsletter Fall 2017 - US Edition
U.S. Newsletter Winter 2014- 2015
U.S. Newsletter Spring 2014
U.S. Newsletter Fall 2013
Case Studies
Discrete Analyzers Designed for the Environment
Advantages of Segmented Flow Analysis
Is Discrete or Continuous Flow Analysis Best?
Safer Method for Total Alkaloids in Tobacco
Discrete Analyzers
Continuous Segmented Flow Analyzers
Customers Only
Contact Us
North, South America
UK, Europe & Africa
Asia
Australia & South Pacific
Registration
X
Home
About SEAL
About SEAL Analytical
Events and Exhibitions
SEAL Press Release
Employment
Technical Support Chemist
Development Chemist
Your Privacy
Markets
Wastewater Analysis
Water Analysis
Olympic Water Quality Danger
Case Study - Lake Superior University AQ1
AutoAnalyzer Protects BASF From Impurities in Water
University of Portsmouth
An Australian Lab's Key to Success
Seawater Analysis
Ocean-going lab- Real test of Nutrient Analyzer
HOT Case Study
Australian Institute of Marine Science
Researchers investigate ultra-low Mediterranean nutrient levels
Soil & Plant Analysis
Fertilizer Analysis
Pharmaceutical
Food& Beverage Analysis
Tobacco Analysis
Products
Discrete Analyzers
AQ400 Discrete Analyzer
AQ300 Discrete Analyzer
AQ270 Discrete Analyzer
AQ2 Discrete Analyzer
AQ2 Automatizada Integrated Analyzer
AQ Software
Segmented Flow Analyzers
QuAAtro39 AutoAnalyzer
AA500 AutoAnalyzer
AA3 HR AutoAnalyzer
AA100 AutoAnalyzer
AutoAnalyzer II
AACE AutoAnalyzer Software
Robotic Handling Systems
MiniLab BOD Analyzer
MiniLab Multi-Parameter Robot
PH & Electrical Conductivity
Digestion
Digestion Block-BD50/ BD28
Block Digestion Temp Accuracy
SmartBlock ll Graphite Heating Block
Deena3 Metals Digestion
DEENA II Metals Digestion
Samplers
AutoSamplers
Methods
Methods Overview
AutoAnalyzer Methods
AutoAnalyzer Multi-test Methods
QuAAtro Multi-test Methods
AA3 PO4 Application Notes
QuAAtro P04 Application Notes
Discrete Methods
Discrete Analyzer EPA Methods
Support
Technical Support
Support Contracts
Service and Repairs
Software Upgrades
Customer Training
AQ400 Customer Support
AQ2 Customer Support
AQ1 Customer Support
AA3 Customer Support
QuAAtro Customer Support
Parts
AutoAnalyzer Parts (AA2-AA3)
Pump Tubes
Transmission Tubing
NOx 4 way Valve Maintenance Kit
AutoAnalyzer Parts AA100-AA1
AutoAnalyzer AA100-AA1 Pump Tubes
QuAAtro - TrAAcs Parts
QuAAtro Pump Tubes
AQ400 Consumables & Parts
AQ2 Consumables & Parts
AQ1 Consumables & Parts
BD28/BD50/ AIM 600 Block Digestion Parts
News
SEAL Newsletter
US Newsletter Winter 2019
US Newsletter Fall 2017 - US Edition
U.S. Newsletter Winter 2014- 2015
U.S. Newsletter Spring 2014
U.S. Newsletter Fall 2013
Case Studies
Discrete Analyzers Designed for the Environment
Advantages of Segmented Flow Analysis
Is Discrete or Continuous Flow Analysis Best?
Safer Method for Total Alkaloids in Tobacco
Discrete Analyzers
Continuous Segmented Flow Analyzers
Customers Only
Contact Us
North, South America
UK, Europe & Africa
Asia
Australia & South Pacific
Registration
Support
Support
QuAAtro Customer Support
QuAAtro Customer Support
Support Available for QuAAtro Users
Customer Support Manual-
Provides instrument information and operational / maintenance checklists needed to operate the QuAAtro at full capacity.
Contact SEAL Analytical
or your local Distributor for your Customer Support Manual.
Exclusive Customer Only Website Content-
Register for a login and password to access Customer Only exclusive website content.
Register here.
Technical Support
Service & Maintenance
Support Contract
Training
Software Upgrades
Customer Support Manual Inclusions:
Maintenance Checklists
The first 3 tabs are set up to organize the Operational / Maintenance Checklists.
Daily / Weekly Checklist
Monthly Maintenance Checklist - Includes "How To" clean and lubricate the pump
12 Month Maintenance Checklist - Includes "How To" Change Photometer lamp & Change Sampler Probe / Sample Line
Service Contract Information
"How To"
The 4th tab is the NEW "How To" Section featuring the following information:
• Daily Startup • Bubble Pattern • Wash Solution Baseline Troubleshooting
• Calculate Reagent Absorbance • Calculate Sensitivity • Sensitivity / Noise Troubleshooting
• Colorimeter Check • Cadmium Column Preparation • Checking Inter-sample Air Bubble
• Building a Diagnostic Package • Opening a diagnostic Package
QuAAtroSystem
This section gives you the detailed information you need nearly every day:
• XY2 / XY3 Sampler - Part numbers, sample line, sample splitters
• Pump tubes, air valves, pump tube chart
• Analytical Manifold - Mixing / heating, cadmium reduction, on-line distillation, dialysis, on-line UV digestion, on-line solvent extraction
• Tubing and Glass connections - How to with Part numbers and recommended connectors
• Detectors - Colorimeter description part numbers and a review of the other available detectors
Multi-Test Manifolds
How do Multi-test manifolds work? And what are the advantages.
• Multi-test Manifold Diagrams
• Multi-test Advantages • Multi-test Methods • Multi-test Chemistry Changeover - Wash out chart
AACE Software
The 7th tab is devoted to the new features in AACE along with how to and why the software is set up for a run.
• AACE release Notes • Sampling Rates
• Software Corrections - Carryover, Baseline Drift, Sensitivity Drift
• Typical Tray Protocol
• Statistics - Standard Deviation, Coefficient of Variation, Correlation Coefficient, Detection Limit
• Calculating Results
CFA / SFA Theory
• Hydraulics - Laminar Flow, Segmented Flow
• Dispersion - Mathematical Model in Segmented Streams, Sources of Dispersion, Wetting Agents
• Steady State
• Advantages of Air-segmented CFA
• Photometry - Lambert-Beer Law
Troubleshooting
• AACE PC Troubleshooting
• Sampler Inter-Sampler Air Bubble
• Troubleshooting Guide • No air bubbles • Bad Bubble Pattern • Vaseline or Sensitivity Drift • High Carryover
• Baseline Noise • Loss of Sensitivity • Spikes at Beginning of Peaks • Baseline elevated after Run
• Baseline elevated at end of run but returns slowly • Fluctuation in Steady State • Downward Sensitivity Drift
• Spikes on Peaks Caused by Air in Flowcell • Rhythmic Pulsing Noise (Every 2 seconds)
• Rhythmic Pulsing Noise (Every 1-3 seconds) • Random Noise (Every 5-15 seconds) • No Steady-State
• Poor Sample Transfer